Powered Signal Conditioners, Trip Amplifiers, Splitter & Calculators


  • SEM1600T

    SEM1600T

    Provides mA or Voltage output for Pt100, T/C or Potentiometer Sensors
    Product Image

    Provides mA or Voltage output for Pt100, T/C or Potentiometer Sensors

    • Accepts RTD, Thermocouple and Slidewire Sensors
    • Current (Active or Passive), Voltage Or Bipolar Voltage Output
    • Powered ( 10 to 32) V AC / (10 to 48) V DC Supply
    • 22 Segment User Linearisation
    • Sensor Offset and Output Alignment
    • Adjustable Input Filter
    • EAC Approval
  • SEM1600VI

    SEM1600VI

    Provides mA or voltage input / output with linearisation option
    Product Image

    Provides mA or voltage input / output with linearisation option

    • (-50 to 50) V or (-50 to 50) mA Input
    • Current, Voltage Or Bipolar Voltage Output
    • Accepts Internal and External Powered Current Loops On Input and Output
    • Powered ( 10 to 32) V AC / (10 to 48) V DC Supply
    • 22 Segment User Linearisation
    • USB Port configuration
    • EAC Approval
  • SEM1600F

    SEM1600F

    For Frequency / Pulse Sensors and provides mA or volt output
    Product Image

    For Frequency / Pulse Sensors and provides mA or volt output

    • Dual or Single Universal Frequency Input(s) Plus Excitation
    • Frequency (0.01 to 65000) Hz Or Counter (DC to 1000) Hz Modes
    • Rate/Totalise, K Factor, M Factor, Maths Functions
    • Second Input Acts As A Reset In Single Channel Mode
    • Volt Free Contact Trip, Latched Trip or Pulse Output Actions
    • Isolated Output For Current, Voltage or Bipolar Voltage
    • AC/DC Power Supply
  • SEM1600B

    SEM1600B

    For load cell sensors. Provides mA or voltage output
    Product Image

    For load cell sensors. Provides mA or voltage output

    • Accepts Up To 4 Load Cells In Parallel
    • Output Current or Voltage Signal
    • Calibration Function
    • Remote Tare Function
    • Power Supply (10 to 32) V AC or (10 to 48) V DC Supply
    • USB Programmable
  • SEM1620

    SEM1620

    Provides 3 Wire Voltage Output For Pt100, Thermocouple and Passive mA Signals
    Product Image

    Provides 3 Wire Voltage Output For Pt100, Thermocouple and Passive mA Signals

    • Pt100,Thermocouple,mV,mA Input
    • (0 to 10), (0 to 5), (2 to 10), (1 to 5) and ( 0 to 1)V DC Output choices
    • Push Button User Trim For In Process Fine Tuning
    • Galvanic Isolation
  • SEM1630

    SEM1630

    2 Relay output for Pt100, Thermocouple Sensors and mV, mA signals
    Product Image

    2 Relay output for Pt100, Thermocouple Sensors and mV, mA signals

    • Suitable for Pt100 or Thermocouple Sensors
    • Suitable for mA or mV signals
    • Dual Relay Outputs 250V AC @ 1A
    • Relay Contacts isolated from each other
    • Galvanic Isolation
    • Simple USB Configuration Port
  • SEM1633

    SEM1633

    2 Relay output for Pt100 / Potentiometer Sensors
    Product Image

    2 Relay output for Pt100 / Potentiometer Sensors

    • Suitable For RTD or Slidewire Sensors
    • High, Low,Deviation and Invert Trip Actions
    • Trip Rating 250 V AC 1A ; 30 V DC 1A
    • Powered ( 10 to 32) V AC / (10 to 48) V DC Supply
    • Input Filter, User Linearisation Functions
    • USB Programmable
  • SEM1636

    SEM1636

    Loop powered trip amplifier with 2 relay outputs
    Product Image

    Loop powered trip amplifier with 2 relay outputs

    • Dual Change Over Relay Output
    • Relay Rating 250V AC 1A; 30V DC 1A
    • Latching Relays In Case Of Loop Failure
    • Powered From 4/20mA Loop
    • Programmable Alarm Functions
    • LED Alarm Indication
    • Programmable Via USB Port
  • SEM1700

    SEM1700

    Universal Input With Dual Relay and Process Output Signal
    Product Image

    Universal Input With Dual Relay and Process Output Signal

    • Rtd, Thermocouple, mV, V, mA and Potentiometer Input
    • Isolated Universal Voltage or Current Output
    • Dual C/O Relay Trip Outputs
    • Universal Power Requirement 22to 250V AC or DC
    • Powers both input and output current loops
    • Simple Configuration Via USB Port
    • EAC Approval
  • SEM1720

    SEM1720

    2 Channel for Pt100, T/C. mA or volt output. Maths functions also
    Product Image

    2 Channel for Pt100, T/C. mA or volt output. Maths functions also

    • Dual Channel With 5 Port Isolation (3.75Kv)
    • Accepts RTD, Thermocouple or Potentiometer Sensors
    • Universal Voltage Or Current Outputs
    • Maths Functions Between Channels
    • Sensor Redundancy Switching
    • Eight User Configured Preset Configurations
  • SEM1750

    SEM1750

    2 Channel mA / voltage on input and output. Maths functions also
    Product Image

    2 Channel mA / voltage on input and output. Maths functions also

    • Dual Channel Voltage Or Current (Active/Passive)Inputs and Outputs
    • 5 Port Isolation To 3.75Kv
    • Can Be Configured As An Active Signal Splitter
    • User Selectable Maths Functions On Each Output Channel
    • Signal Linearisation
    • Signal Simulate Function For Diagnostics