Signal conditioners are used to convert one type of signal to another. For example most instrumentation works with the industry standard 4 to 20mA signal. If you are measuring temperature and you have a signal in ohms from a Pt100 sensor, you can use a signal conditioner to change the ohmic value of the sensor into a mA value that will directly represent the temperature value. This basic principle can be applied to sensors that measure a process and provide signals in mA, voltage, Pt100, thermocouple, pulse, frequency etc they can all be read by the signal conditioner to give the desired output for the rest of the control system.

  • SEM1600T

    SEM1600T

    Provides mA or Voltage output for Pt100, T/C or Potentiometer Sensors
    Product Image

    Provides mA or Voltage output for Pt100, T/C or Potentiometer Sensors

    • Accepts RTD, Thermocouple and Slidewire Sensors
    • Current (Active or Passive), Voltage Or Bipolar Voltage Output
    • Powered ( 10 to 32) V AC / (10 to 48) V DC Supply
    • 22 Segment User Linearisation
    • Sensor Offset and Output Alignment
    • Adjustable Input Filter
    • EAC Approval
  • SEM1600VI

    SEM1600VI

    Provides mA or voltage input / output with linearisation option
    Product Image

    Provides mA or voltage input / output with linearisation option

    • (-50 to 50) V or (-50 to 50) mA Input
    • Current, Voltage Or Bipolar Voltage Output
    • Accepts Internal and External Powered Current Loops On Input and Output
    • Powered ( 10 to 32) V AC / (10 to 48) V DC Supply
    • 22 Segment User Linearisation
    • USB Port configuration
    • EAC Approval
  • SEM1600F

    SEM1600F

    For Frequency / Pulse Sensors and provides mA or volt output
    Product Image

    For Frequency / Pulse Sensors and provides mA or volt output

    • Dual or Single Universal Frequency Input(s) Plus Excitation
    • Frequency (0.01 to 65000) Hz Or Counter (DC to 1000) Hz Modes
    • Rate/Totalise, K Factor, M Factor, Maths Functions
    • Second Input Acts As A Reset In Single Channel Mode
    • Volt Free Contact Trip, Latched Trip or Pulse Output Actions
    • Isolated Output For Current, Voltage or Bipolar Voltage
    • AC/DC Power Supply
  • SEM1600B

    SEM1600B

    For load cell sensors. Provides mA or voltage output
    Product Image

    For load cell sensors. Provides mA or voltage output

    • Accepts Up To 4 Load Cells In Parallel
    • Output Current or Voltage Signal
    • Calibration Function
    • Remote Tare Function
    • Power Supply (10 to 32) V AC or (10 to 48) V DC Supply
    • USB Programmable
  • SEM1620

    SEM1620

    Provides 3 Wire Voltage Output For Pt100, Thermocouple and Passive mA Signals
    Product Image

    Provides 3 Wire Voltage Output For Pt100, Thermocouple and Passive mA Signals

    • Pt100,Thermocouple,mV,mA Input
    • (0 to 10), (0 to 5), (2 to 10), (1 to 5) and ( 0 to 1)V DC Output choices
    • Push Button User Trim For In Process Fine Tuning
    • Galvanic Isolation
  • SEM1630

    SEM1630

    2 Relay output for Pt100, Thermocouple Sensors and mV, mA signals
    Product Image

    2 Relay output for Pt100, Thermocouple Sensors and mV, mA signals

    • Suitable for Pt100 or Thermocouple Sensors
    • Suitable for mA or mV signals
    • Dual Relay Outputs 250V AC @ 1A
    • Relay Contacts isolated from each other
    • Galvanic Isolation
    • Simple USB Configuration Port
  • SEM1633

    SEM1633

    2 Relay output for Pt100 / Potentiometer Sensors
    Product Image

    2 Relay output for Pt100 / Potentiometer Sensors

    • Suitable For RTD or Slidewire Sensors
    • High, Low,Deviation and Invert Trip Actions
    • Trip Rating 250 V AC 1A ; 30 V DC 1A
    • Powered ( 10 to 32) V AC / (10 to 48) V DC Supply
    • Input Filter, User Linearisation Functions
    • USB Programmable
  • SEM1636

    SEM1636

    Loop powered trip amplifier with 2 relay outputs
    Product Image

    Loop powered trip amplifier with 2 relay outputs

    • Dual Change Over Relay Output
    • Relay Rating 250V AC 1A; 30V DC 1A
    • Latching Relays In Case Of Loop Failure
    • Powered From 4/20mA Loop
    • Programmable Alarm Functions
    • LED Alarm Indication
    • Programmable Via USB Port
  • SEM1700

    SEM1700

    Universal Input With Dual Relay and Process Output Signal
    Product Image

    Universal Input With Dual Relay and Process Output Signal

    • Rtd, Thermocouple, mV, V, mA and Potentiometer Input
    • Isolated Universal Voltage or Current Output
    • Dual C/O Relay Trip Outputs
    • Universal Power Requirement 22to 250V AC or DC
    • Powers both input and output current loops
    • Simple Configuration Via USB Port
    • EAC Approval
  • SEM1720

    SEM1720

    2 Channel for Pt100, T/C. mA or volt output. Maths functions also
    Product Image

    2 Channel for Pt100, T/C. mA or volt output. Maths functions also

    • Dual Channel With 5 Port Isolation (3.75Kv)
    • Accepts RTD, Thermocouple or Potentiometer Sensors
    • Universal Voltage Or Current Outputs
    • Maths Functions Between Channels
    • Sensor Redundancy Switching
    • Eight User Configured Preset Configurations
  • SEM1750

    SEM1750

    2 Channel mA / voltage on input and output. Maths functions also
    Product Image

    2 Channel mA / voltage on input and output. Maths functions also

    • Dual Channel Voltage Or Current (Active/Passive)Inputs and Outputs
    • 5 Port Isolation To 3.75Kv
    • Can Be Configured As An Active Signal Splitter
    • User Selectable Maths Functions On Each Output Channel
    • Signal Linearisation
    • Signal Simulate Function For Diagnostics

Accepted Payment Methods