SEM1600F

Virtausmittarin hoitoaine
Pyydä tarjousSähköposti: support@status.co.uk
  • Hyväksyy prosessipulssisignaaleja välillä (0.1–65 kHz)
  • Laskuritilassa hyväksyy (DC - 1000) Hz
  • mV, mA, PNP, NPN, TTL-yhteensopiva
  • Namur-anturiyhteensopiva
  • Nopeus, summaus, k-kerroin, m-kerroin, matematiikka
  • mA-, jännite-, bipolaarinen jännite- ja relelähdöt

The SEM1600/F, flow meter conditioner is suitable for flow sensor’s outputs including mV, mA, PNP, NPN and TTL.  Flow or count, rate, totalise are available.

The product has a built-in capability to operate as a dual input which allows differential measurement. Flow in  / flow out can be calculated meaning fluid can be controlled in or out of a device in either direction.

When operated in signal channel mode, the discrete input can be programmed to reset the total counter, batch counter or latched relay. The input can also be programmed to control the total counter direction with a combination of count-up, count-down or halt modes available.

THREE OPERATING MODES

  • Basic frequency mode to process signal mode, analogue + relay outputs.
  • Advanced frequency mode with K factor, M factor, totalize, rate, maths functions, process signal, 12-point user linearisation for channel A using meter correction, analogue + relay outputs.
  • Pulse counter mode with K factor, totalize, maths functions, process signal, analogue + relay outputs.

USB CONFIGURATION The product uses a built-in USB port for configuration, together with a simple to use, free menu-driven software configuration tool, allowing the user to take advantage of the products’ comprehensive specification.

ANALOGUE OUTPUT The output stage offers either voltage, bipolar voltage or active/passive current re- transmission signals. The output signal can be ranged to a scale anywhere within the process range.

RELELÄHTÖ A volt free output contact is provided capable of operating as either a trip relay, latched relay or pulsed relay. High and low-level relay functions are also available. Trip options on rate, count, totalize or maths functions.

SIGNAL RETRANSMISSION SCALING The input signal range for retransmission can be selected from any part of the maximum input capability. The output signal range can be selected from any part of the total output capability, for example (0 to 12) litres per minute input to (1 to 5) mA output.

Overall, this frequency / pulse signal conditioner is an extremely powerful product and is designed and built  in the UK.

 


Online-laskimet

Käytä online-laskimiamme 24/7!

Katso resurssit

Saat apua liikkeellä ollessasi sovellustemme kautta!

Lataa ilmaiset sovelluksemme sekä Apple- että Android-laitteille.

LUE LISÄÄ
Kääntää "

Kuinka voimme auttaa?

Kerro meille, mitä haluat saavuttaa, niin pyrimme tarjoamaan parhaan ratkaisun ja hinnan. Puhutko mieluummin jollekin?

Soita 01684 296818.

    KUINKA KUULIT MEISTÄ?

    Teemme parhaamme vastataksemme 4 työtunnin kuluessa.

    Jos tarvitset nopeampaa vastausta, soita meille
    01684 296818.