SEM1600T - Smart RTD, Thermocouple, Slidewire Active Signal Condtioner

  • Accepts RTD, Thermocouple and Slidewire Sensors
  • Current (Active or Passive), Voltage Or Bipolar Voltage Output
  • Powered ( 10 to 32) V AC / (10 to 48) V DC Supply
  • 22 Segment User Linearisation
  • Sensor Offset and Output Alignment
  • Adjustable Input Filter


The SEM1600T accepts resistance or mV signals from RTD, Slidewire or Thermocouple sensors. The flexible design allows the use of any resistive sensor within the range of (10 to 10500) 0hms including Pt100, 500, 1000, Ni or Cu sensors, slide wire sensors up to 100 K Ohms and 13 different thermocouple types. Other sensor characteristics or your own 22 point linearisation characteristic (for slidewire, linear resistance or mV) can be downloaded into the product enabling you to adapt it exactly to your application.

The output stage offers either voltage, bipolar voltage or current re-transmission signals. The retransmission signal can be ranged to a scale anywhere within the input process range. A transmitter power supply is provided on the output meaning the product can accept sink or source mA applications. While the voltage output will drive 2 mA into 5 K0 @ 10 V

For ease of use, a high efficiency switch mode power supply is fitted as standard and does not require any adjustment between ac or dc applications. Operating voltages are (10 to 48) V dc and (10 to 32) V ac.


Status Instruments Ltd · Green Lane Business Park, Green Lane, Tewkesbury, Glos, GL20 8DE Tel: +44 1684 296818 · Fax: +44 1684 293746 · E-mail: sales@status.co.uk
10000